Audi 80/90/Coupe

since 1986-1991 release

Repair and operation of the car



Audi 80/90/Coupe
+ 1.2. Identification of the car
- 2. Engines, carburetors
   2.1.2. Removal and installation of the engine (5-cylinder models)
   2.1.3. Dismantling and assembly of engines
   2.1.4. Head of the block of cylinders, gas distribution mechanism
   - 2.2. Engine electric equipment
      2.2.2. Tension of a maple belt
      2.2.3. Maple belt of the generator of alternating current
      2.2.4. Regulator of tension of the generator of alternating current
      2.2.5. Vacuum amplifier
      2.2.6. Vacuum final valves
      2.2.7. The switches installed on a steering column
      2.2.8. Check of vacuum system
   + 2.3. Carburetors
3. Lubrication system
+ 4. Cooling system
+ 5. Fuel system
+ 6. Exhaust system
+ 7. System of ignition
+ 8. Transmission
+ 9. Suspension brackets, wheels
+ 10. Brake system
+ 11. Steering
+ 12. Body, salon
+ 13. Air conditioning system
+ 14. Electric equipment


2.2.5. Vacuum amplifier

GENERAL INFORMATION

Basic elements of system cruise control


1. Main control unit
2. Grounding socket
under an instrument guard
3. Control socket
it is used only by production
4. Connection socket
with 3 plugs, blue color
5. Connecting draft of the vacuum amplifier
6. Vacuum amplifier
7. Vacuum hose
8. Engine of control of level of depression
9. Rubber laying
10. The vacuum final valve on a coupling pedal
11. The vacuum final valve on a pedal of a toromoz
12. Stoplight switch
13. The switch on a steering column
14. Instrument guard
I will corrode connections of the sensor of speed

PERFORMANCE ORDER
1) remove a glove compartment
2) behind an instrument guard unscrew the screw with a head under the crosswise screw-driver
3) remove the control unit and disconnect the electronic socket of connection

Connecting draft of the vacuum amplifier, adjustment

PERFORMANCE ORDER
1) check that the butterfly valve was closed
2) turn an adjusting nut (1) so that between the plug and a contact plate (2) there was a gap of 0.1-0.3 mm

Vacuum amplifier, removal

PERFORMANCE ORDER
1) disconnect clips or turn off screws of fastening of connecting draft
2) remove a vacuum hose
3) remove the vacuum amplifier from an arm (it is specified by an arrow)
4) the nut inhaling moment – 25 N. of m.